<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>15503</ErrorNumber>
<ErrorFamily>Autoloader</ErrorFamily>
<ErrorMessage>
ALE: ALE board still in reset
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_VLF</Text></ListItem>
<ListItem><Text>Platesetter_VLF</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The ALE board has been reset for some reason.  Confirm proper operation
of the ale board.  Re-seat the board (with the power off) and reset the
platesetter.  Watch for error messages as the ALE LCA file is downloaded
during the startup sequence.  Check the power supplies to the ALE.  Look
for causes of static discharge which may have reset the ALE board.
Replace ALE board if no cause for the problem is found, and return the
ALE board to a VLFTrendsetter or Platesetter_VLF system engineer for
diagnosis.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
This is not an operator-serviceable error.  Call Creo response to log
the error.  Reset the machine to continue production.
</text></DescriptionText>
</OperatorAction>
<Cause>
The ALE_RESET bit of the ale.version register has been set for some reason.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:33:08 2008 PST